Alcohol Breath Analyser Inbuilt Printer- KT4000P
Breath alcohol analyzer is the first and most classic alcohol tester designed for police use at the roadside to test drivers for drunk driving. More than 10 years of use provies its stability and practicability.
Product Features
- Quick and Precise Analysis: 32bit embedded processor secures high performance of the system.
- UK made Electrochemical/Fuel cell sensor: Highly specificity to alcohol, unaffected by other possible breath contaminants.
- Compact Gas Circuit Design and Advanced Analysis process: Assure fast, accurate and stable testing results.
- Built-in Printer: Fast printing process and clear print-outs. Can be detached from main body and be replaced by a piece of spare lithium-ion cell.
- Color LCD Touch Screen: 2.8 inch 320*240 dot matrix screen provides intuitive operation.
- Safe & Easy to Use: All measurement functions are controlled via a single key, while menu navigation is by three menu keys
- Memory Capacity: Data storage of 40,000 test results. Any test results can be easily recalled, printed or downloaded to a computer for statistical analysis and back up.
- Built-in GPS Function: Satellite positioning of inspection location.(Optional)
- Mouthpiece: Specially designed one-way mouthpiece.
Technical Data
Details | Technical Data | ||
Principle of measurement | Electrochemical Sensor, alcohol-specific | ||
Measurement Range (BrAC) | 0.000mg/L~2.000mg/L | ||
Resolution | 0.001 mg/L | ||
Accuracy: Max. Measuring error, in relation to the ethanol standard |
Ethanol Vapor Concentration C /(mg/L) |
Deviation | |
C<0.400 | ±0.020mg/L | ||
0.400≤C<1.000 | ±5% | ||
C≥1.000 | ±20% | ||
Calibration | Every 6 months | ||
Temperature range- operation | -10°C~45°C | ||
Temperature range-storage | -30°C~70°C | ||
Optimum Storage Conditions | Temperature: 20°C ±5°C, Humidity: <80%RH, Pressure: 86kPa~106kPa No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device |
||
Blowing Time | 3 seconds (breath flow:≥20L/min) | ||
Warm-up Time | 6 seconds after switching on | ||
Recovery Time | 1-5 minutes, depends on Ethanol Vapor Concentration | ||
Analysis Time | Less than 10 seconds | ||
Display | 2.8 inch color touch screen | ||
Memory Capacity | Stores 40,000 measured values with date and time (data can be transferred to a PC or printer) |
||
Communication Method for Printer | Bluetooth | ||
Printer | Micro Thermal printer | ||
Dimensions(L x W x H) | Approx. 182mm×80mm×34mm | ||
Number of Measurements per Battery Pack | More than 500 times (under ambient conditions) |